Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Journal of Pharmaceutical Analysis ; (6): 190-199, 2015.
Article in Chinese | WPRIM | ID: wpr-467109

ABSTRACT

An analytical method based on solid phase extraction was developed and validated for analysis of adefovir in human plasma. Adefovir-d4 was used as an internal standard and Synergi MAX RP80A (150 mm × 4.6 mm, 4μm) column provided the desired chromatographic separation of compounds followed by detection with mass spectrometry. The method used simple isocratic chromato-graphic condition and mass spectrometric detection in the positive ionization mode. The calibration curves were linear over the range of 0.50–42.47 ng/mL with the lower limit of quantitation validated at 0.50 ng/mL. Matrix effect was assessed by post-column infusion experiment to monitor phospholipids and post-extraction addition experiment was performed. The degree of matrix effect for adefovir was determined as 7.5%and ion-enhancement in five different lots of human plasma was 7.1%and had no impact on study samples analysis with 4.5 min run time. The intra- and inter-day precision values were within 7.7% and 7.8%, respectively, for adefovir at the lower limit of quantification level. Validated bioanalytical method was successfully applied to clinical sample analysis.

2.
Pakistan Journal of Pharmaceutical Sciences. 2013; 26 (3): 465-472
in English | IMEMR | ID: emr-142605

ABSTRACT

In this study a rapid, simple and sensitive assay to quantify clozapine in human plasma by using reverse phase high performance liquid chromatographic method has been developed. Clozapine was extracted from human plasma using a mixture of chloroform: n-hexane 50:50 employing liquid- liquid extraction method. The calibration curve was found to be linear in the concentration range of 25-800 ng/ml. The inter day and intra day assay accuracy and precision fulfilled the criteria specified by USFDA, Guidance for industry: bioanalytical method validation. Clozapine was found to be stable in human plasma after 6 h incubation at room temperature, 50 days storage at -27[degree sign] C and freeze thaw cycles, as well as after reconstitution with mobile phase after 24 h of storage in refrigerator. The validated method offers the advantage of using minimum injection volume [25micro l] and plasma sample volume [300micro l]. The extraction method is simple and single step with no back extraction step, thus, making this method applicable to determination of pharmacokinetic profiles and parameters


Subject(s)
Humans , Clozapine/blood , Clozapine/chemistry , Liquid-Liquid Extraction/methods , Reproducibility of Results , Sensitivity and Specificity , Antipsychotic Agents/blood , Calibration , Validation Studies as Topic
SELECTION OF CITATIONS
SEARCH DETAIL